四川中光防雷科技股份有限公司
Products
ZGG40-75/275/320/385/440(1+1)hs
 
General                                                                                 
         This series is made up of one MOV power modules, one GDT power module and a base.
The ZGG40-75(1+1)hs is used for secondary protection of L(+)-N(-), N(-)-PE respectively. It is applied to the low-voltage AC power distribution system or DC power supply and connected with equipment in parallel.
The ZGG40-275/320/385/440(1+1)hs are used for secondary protection of L-N, N-PE respectively.
Features                                                                                 
         1Anti-reverse plug.
         2High discharge capacity, low residual voltage.
         3Overtemperature protection.
         4Failure indication and centralized remote signalling alarm dry contacts.
         5Enclosure IP20, UL94 V-0.
Standards Complied                                                                            
         IEC 61643-11 :2011 Low-voltage surge protective devices - Part 11: Surge protective devices connected to low-voltage power systems – Requirements and tests
         EN 61643-11:2012 Low-voltage surge protective devices - Part 11: Surge protective devices connected to low-voltage power systems – Requirements and tests
Technical Data                                                                             
Operating Environment                                                                            
Temperature  -40℃~85℃
Relative humidity 5 %~95 %
altitude -500 m~﹢4000 m
Technical Parameters
Model ZGG40-75(1+1)hs ZGG40-275(1+1)hs ZGG40-320(1+1)hs ZGG40-385(1+1)hs ZGG40-440(1+1)hs
SPD according to IEC 61643-11 Class Ⅰ and Class Ⅱ Class Ⅱ Class Ⅱ Class Ⅱ Class Ⅱ
SPD according to EN 61643-11 Type 1 and Type 2 Type 2 Type 2 Type 2 Type 2
Max. continuous operating voltage UC L-N: 75 V AC,100 V DC ;N-PE: 150 V AC L-N:275 V AC; N-PE:260 V AC L-N:320 V AC; N-PE:260 V AC L-N:385 V AC; N-PE:260 V AC L-N:440 V AC; N-PE:260 V AC
Operating frequency - 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
Nominal discharge current In (8/20μs) L-N:15 kA, N-PE:20 kA 20 kA 20 kA 20 kA 20 kA
Max. discharge current Imax (8/20μs) 40 kA
Impulse current Iimp(10/350μs) L-N:4 kA - - - -
Voltage protection level Up L-N:0.65 kV, N-PE:1 kV L-N:1.4 kV; N-PE:1.5 kV L-N:1.6 kV; N-PE:1.5 kV L-N:1.8 kV; N-PE:1.5 kV L-N:2.2 kV; N-PE:1.5 kV
Follow Current Interrupting Rating Ifi N-PE:100 Arms
Max. backup fuse 63 A gL/gG 80 A gL/gG 80 A gL/gG 80 A gL/gG 80 A gL/gG
Connection mode parallel
Protection mode L(+)-N(-), N(-)-PE L-N、N-PE L-N、N-PE L-N、N-PE L-N、N-PE
Response time  tA   L-N:≤25 ns;N-PE:≤100 ns
Cross-sectional Area Stranded: 1.5 mm2~25 mm2, Solid: 1.5 mm2~35 mm2
Max. Cross-sectional Area For Remote signalling terminals 1.5 mm2
Intensity of Remote Signalling Alarm Contact AC: 250 V/0.5 A   125 V/1 A    DC: 30 V/0.1 A
Torque: Connecting Terminal/Remote Signalling Interface 2.5 N•m /0.25 N•m
Degree of Protection (IP Code) IP 20
Installation system TN、TT TT、TN TT、TN TT、TN TT、TN、IT
Mounting on DIN 35 mm rail
Flammability UL 94 V-0
Circuit Diagram                                                                      
 

Configuration